Item
Supply voltage
drift
Band switching
voltage
Symbol
∆fst1
∆fst2
∆fst3
∆fst4
VSWV
VSWU
Measurement conditions
VHF operation fOSC=100 MHz
∆f when VCC 5 V ± 5 % variation
VHF operation fOSC=470 MHz
∆f when VCC 5 V ± 5 % variation
UHF operation fOSC=470 MHz
∆f when VCC 5 V ± 5 % variation
UHF operation fOSC=895 MHz
∆f when VCC 5 V ± 5 % variation
VHF operation
UHF operation
CXA3225N
Min. Typ. Max. Unit
±200 kHz
±250 kHz
±150 kHz
±150 kHz
0
0.5 V
3
5.5 V
—7—