RA351 thru RA357
Figure 1
Typical Forward Characteristics
20
100
60
40
20
Amps 10
.6
.4
25°C
.2
.1
.06
.04
.02
.01
.4
.6 .8
1.0 1.2 1.4
Volts
Instantaneous Forward Current - Amperesversus
Instantaneous Forward Voltage - Volts
Figure 3
Junction Capacitance
MCC
TM
Figure 2
Micro Commercial Components
Forward Derating Curve
35
30
25
20
Amps
15
10
Single Phase, Half Wave
60Hz Resistive or Inductive Load
0
0
50 75 100 125 150 175
°C
Average Forward Rectified Current - Amperesversus
Case Temperature -°C
Figure 4
Peak Forward Surge Current
500
400
300
200
Amps
100
50
0
1
2
4 6 8 10 20
Cycles
40 60 80 100
Peak Forward Surge Current - Amperesversus
Number Of Cycles At 60Hz - Cycles
100
60
40
20
pF
10
6
4
2
1
.1
Revision: 5
TJ=25°C
.2 .4
12
4
Volts
10 20 40
100 200 400
Junction Capacitance - pFversus
Reverse Voltage - Volts
www.mccsemi.com
2 of 3
1000
2008/06/24