Micrel, Inc.
KSZ8841-16/32 MQL/MVL/MBL
Selection of Isolation Transformers
A 1:1 isolation transformer is required at the line interface. An isolation transformer with integrated common-mode choke
is recommended for exceeding FCC requirements.
Table 27 gives recommended transformer characteristics.
Parameter
Turns ratio
Open-circuit inductance (min)
Leakage inductance (max)
Inter-winding capacitance (max)
D.C. resistance (max)
Insertion loss (max)
HIPOT (min)
Value
1 CT : 1 CT
350µH
0.4µH
12pF
0.9Ω
1.0dB
1500Vrms
Test Condition
100mV, 100kHz, 8mA
1MHz (min)
0MHz – 65MHz
Table 27. Transformer Selection Criteria
Magnetic Manufacturer Part Number
Auto MDI-X
Pulse
Pulse (low cost)
Transpower
Bel Fuse
Delta
LanKom
TDK (Mag Jack)
H1102
Yes
H1260
Yes
HB726
Yes
S558-5999-U7
Yes
LF8505
Yes
LF-H41S
Yes
TLA-6T718
Yes
Table 28. Qualified Single Port Magnetics
Number of Port
1
1
1
1
1
1
1
Selection of Reference Crystal
Chacteristics
Frequency
Frequency tolerance (max)
Load capacitance (max)
Series resistance
Value
25
±50
20
25
Units
MHz
ppm
pF
Ω
Table 29. Typical Reference Crystal Characteristics
October 2007
100
M9999-102207-1.6