L9217A/G Low-Cost Line Interface
with Reverse Battery and PPM
Data Sheet
November 2001
Electrical Characteristics
Minimum and maximum values are testing requirements in the temperature range of 25 °C to 85 °C and battery
range of –24 V to –70 V. These minimum and maximum values are guaranteed to –40 °C based on component
simulations and design verification of samples, but devices are not tested to –40 °C in production. The test circuit
shown in Figure 4 is used, unless otherwise noted. Positive currents flow into the device.
Typical values are characteristics of the device design at 25 °C based on engineering evaluations and are not part
of the test requirements. Supply values used for typical characterization are VCC = 5.0 V, VBAT = –48 V, unless oth-
erwise noted.
Table 4. Power Supply
Parameter
Min
Power Supply—Powerup, No Loop Current:
ICC
—
IBAT (VBAT = –48 V)
—
Power Dissipation (VBAT = –48 V)
—
Power Supply—Scan, No Loop Current:
ICC
—
IBAT (VBAT = –48 V)
—
Power Dissipation (VBAT = –48 V)
—
Power Supply—Disconnect, No Loop Current:
ICC
—
IBAT (VBAT = –48 V)
—
Power Dissipation (VBAT = –48 V)
—
Power Supply Rejection 500 Hz to 3 kHz
(See Figures 5, 6, 16, and 17.)1:
VCC
30
VBAT
36
Thermal Protection Shutdown (Tjc)1
150
Thermal Resistance Still Air, Junction to Ambient (θJA)1, 2:
Natural Convection 2S2P Board
—
Natural Convection 2S0P Board
—
Wind Tunnel 100 Linear Feet per Minute (LFPM) 2S2P Board
—
Wind Tunnel 100 Linear Feet per Minute (LFPM) 2S0P Board
—
Typ
5.2
–2.66
154
3.4
–0.9
57
1.9
–0.1
14
—
—
165
30
43
27
36
1. This parameter is not tested in production. It is guaranteed by design and device characterization.
2. Airflow, PCB board layers, and other factors can greatly affect this parameter.
Max
Unit
6.5
mA
–2.95
mA
175
mW
4.3
mA
–1
mA
70
mW
—
mA
—
mA
—
mW
—
dB
—
dB
—
°C
—
°C/W
—
°C/W
—
°C/W
—
°C/W
8
Agere Systems Inc.