LMV321, LMV358, LMV324
MAXIMUM RATINGS
Symbol
Rating
Value
Unit
VS
VIDR
VICR
Supply Voltage (Operating Range VS = 2.7 V to 5.5 V)
Input Differential Voltage
Input Common Mode Voltage Range
Maximum Input Current
5.5
V
$Supply Voltage
V
−0.5 to (V+) + 0.5
V
10
mA
tSo
Output Short Circuit (Note 1)
TJ
Maximum Junction Temperature (Operating Range −40°C to 85°C)
qJA
Thermal Resistance:
SC−70
Continuous
150
280
°C
°C/W
Micro8
238
TSOP−5
333
UDFN8 (1.2 mm x 1.8 mm x 0.5 mm)
350
SOIC−8
212
SOIC−14
156
TSSOP−14
190
Tstg
Storage Temperature
Mounting Temperature (Infrared or Convection −20 sec)
−65 to 150
°C
235
°C
VESD
ESD Tolerance
LMV321
Machine Model
Human Body Model
LMV358/324
Machine Model
Human Body Mode
V
100
1000
100
2000
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may
affect device reliability.
1. Continuous short−circuit operation to ground at elevated ambient temperature can result in exceeding the maximum allowed junction
temperature of 150°C. Output currents in excess of 45 mA over long term may adversely affect reliability. Shorting output to either V+
or V− will adversely affect reliability.
http://onsemi.com
3