LTC4311
PIN FUNCTIONS
BUS1: Active Pull-up for Bus. Connect to either clock line
or data line for 2-wire bus.
BUS2: Active Pull-up for Bus. Connect to either clock line
or data line for 2-wire bus.
ENABLE: Device Enable Input. This is a 1V nominal digital
threshold input pin. For normal operation drive ENABLE
to a voltage greater than 1.5V. Driving ENABLE below the
0.4V threshold puts the device in a low (<5μA) current
shutdown mode and puts the BUS pins in a high imped-
ance state. If unused, connect to VCC.
EXPOSED PAD (DFN Package Only): Exposed Pad may
be left open or connected to device ground.
GND: Device Ground. Connect this pin to a ground plane
for best results.
VCC: Supply Voltage Input. Connect this pin to bus supply
and place a bypass capacitor of at least 0.01μF close to
VCC for best results.
BLOCK DIAGRAM
BUS1
BUS2
ENABLE
5mA
SLEW RATE
DETECTOR
5mA
SLEW RATE
DETECTOR
+
VTHR
–
+
VTHR
–
+
VCC – 0.4
–
+
VCC – 0.4
–
+
1V
–
VCC
CONTROL
LOGIC AND
INTERNAL SLEW
COMPARATOR
GND
4311 BD
4311fa
5