MC10164
ELECTRICAL CHARACTERISTICS
Characteristic
Power Supply Drain Current
Input Current
Output Voltage
Logic 1
Output Voltage
Logic 0
Threshold Voltage Logic 1
Threshold Voltage Logic 0
Switching Times (50Ω Load)
Propagation Delay
Rise Time
Fall Time
(20 to 80%)
(20 to 80%)
Symbol
IE
IinH
IinL
VOH
VOL
VOHA
VOLA
t4+15+
t4–15–
t7+15+
t7–15–
t2+15–
t2–15+
t+
t–
Pin
Under
Test
8
2
4
15
15
15
15
15
15
15
15
15
15
15
15
–30°C
Min
Max
83
425
0.5
–1.060 –0.890
–1.890 –1.675
–1.080
–1.655
1.5
4.9
1.5
4.9
1.9
6.5
1.9
6.5
0.9
3.5
0.9
3.5
0.9
3.3
0.9
3.3
Test Limits
+25°C
Min
Typ
Max
60
75
265
0.5
–0.960
–0.810
–1.850
–1.650
–0.980
–1.630
1.5
3.0
4.7
1.5
3.0
4.7
2.0
4.0
6.2
2.0
4.0
6.2
1.0
2.0
3.1
1.0
2.0
3.1
1.1
2.0
3.3
1.1
2.0
3.3
+85°C
Min
Max
83
265
0.3
–0.890 –0.700
–1.825 –1.615
–0.910
–1.595
1.6
5.0
1.6
5.0
2.2
6.7
2.2
6.7
1.0
3.3
1.0
3.3
1.2
3.6
1.2
3.6
Unit
mAdc
µAdc
µAdc
Vdc
Vdc
Vdc
Vdc
ns
ELECTRICAL CHARACTERISTICS (continued)
TEST VOLTAGE VALUES (Volts)
@ Test Temperature
–30°C
VIHmax
–0.890
VILmin
–1.890
VIHAmin
–1.205
VILAmax
–1.500
VEE
–5.2
+25°C –0.810
–1.850
–1.105
–1.475
–5.2
+85°C –0.700
–1.825
–1.035
–1.440
–5.2
Characteristic
Power Supply Drain Current
Input Current
Output Voltage
Output Voltage
Threshold Voltage
Threshold Voltage
Switching Times
Logic 1
Logic 0
Logic 1
Logic 0
(50Ω Load)
Symbol
IE
IinH
IinL
VOH
VOL
VOHA
VOLA
Pin
Under
Test
8
2
4
15
15
15
15
TEST VOLTAGE APPLIED TO PINS LISTED BELOW
VIHmax
4
4,9
9
4,9
9
+1.11V
VILmin
4
VIHAmin
VILAmax
Pulse In
2
2
Pulse Out
VEE
8
8
8
8
8
8
8
–3.2 V
(VCC)
Gnd
1,16
1,16
1,16
1,16
1,16
1,16
1,16
+2.0 V
Propagation Delay
t4+15+
15
9
t4–15–
15
9
t7+15+
15
5
t7–15–
15
5
t2+15–
15
7,5
t2–15+
15
7,5
Rise Time
(20 to 80%)
t+
15
9
4
15
8
1,16
4
15
8
1,16
7
15
8
1,16
7
15
8
1,16
2
15
8
1,16
2
15
8
1,16
4
15
8
1,16
Fall Time
(20 to 80%)
t–
15
9
4
15
8
1,16
Each MECL 10,000 series circuit has been designed to meet the dc specifications shown in the test table, after thermal equilibrium has been
established. The circuit is in a test socket or mounted on a printed circuit board and transverse air flow greater than 500 linear fpm is maintained.
Outputs are terminated through a 50–ohm resistor to –2.0 volts. Test procedures are shown for only one gate. The other gates are tested in the
same manner.
http://onsemi.com
2