OKI Semiconductor
FEDL7029-03
ML7029
APPENDIX
When the Sampling Frequency is 16 kHz or Higher:
This device enables the operation at 16 kHz or higher sampling frequencies under conditions below. However,
be aware that the AC characteristics are not guaranteed under these conditions.
Operating Conditions at Sampling Frequency = 19 kHz
Parameter
Power Supply Voltage
Operating Temperature Range
Digital Input High Voltage
Symbol
Condition
VDD Voltage must be fixed
Ta
—
VIH
Digital input pin
Min.
3.0
–25
0.95 ×
VDD
Digital Input Low Voltage
VIL
Digital input pin
0
Master Clock Frequency
fMCK1
MCK
—
Master Clock Frequency Accuracy fMCK2
MCK
–0.01%
Sampling Frequency
fSYNC
SYNC
—
Master Clock Duty Ratio
DMCK
—
40
Transmit S/N Ratio
(at 3 dBm0 input)
SD19T1
—
—
Transmit S/N Ratio
(at –40 dBm0 input)
SD19T2
—
—
Receive S/N Ratio
(at 3 dBm0 input)
SD19R1
—
—
Receive S/N Ratio
(at –40 dBm0 input)
SD19R2
—
—
Typ.
—
—
—
24.624
SYNC
× 1296
19
—
46.2
24.8
45.4
38.0
Max.
3.6
+50
VDD
0.05 ×
VDD
—
+0.01
—
70
—
—
—
—
Unit
V
°C
V
V
MHz
MHz
kHz
%
dB
dB
dB
dB
25/29