PRESSURE (P1)/VACUUM (P2) SIDE IDENTIFICATION TABLE
Freescale Semiconductor designates the two sides of the
Freescale Semiconductor pressure sensor is designed to
pressure sensor as the Pressure (P1) side and the Vacuum
operate with positive differential pressure applied, P1 > P2.
(P2) side. The Pressure (P1) side is the side containing
The Pressure (P1) side may be identified by using the
silicone gel which isolates the die from the environment. The
table below.
Part Number
MPXV5004GC6U/T1
MPXV5004G6U/T1
MPXV5004GC7U
MPXV5004G7U
MPXV5004GP
MPXV5004DP
MPXV5004GVP
Case Type
482A
482
482C
482B
1369
1351
1368
Pressure (P1) Side Identifier
Side with Port Attached
Stainless Steel Cap
Side with Port Attached
Stainless Steel Cap
Side with Port Attached
Side with Port Marking
Stainless Steel Cap
INFORMATION FOR USING THE SMALL OUTLINE PACKAGE (CASE 482)
MINIMUM RECOMMENDED FOOTPRINT FOR SURFACE
MOUNTED APPLICATIONS
Surface mount board layout is a critical portion of the total
design. The footprint for the surface mount packages must be
the correct size to ensure proper solder connection interface
between the board and the package. With the correct
footprint, the packages will self align when subjected to a
solder reflow process. It is always recommended to design
boards with a solder mask layer to avoid bridging and
shorting between solder pads.
0.660
16.76
0.100 TYP 8X
2.54
0.060 TYP 8X
1.52
0.300
7.62
0.100 TYP 8X
2.54
inch
mm SCALE 2:1
Figure 5. SOP Footprint (Case 482)
MPXV5004G
4
Sensors
Freescale Semiconductor