Specifications RURP640CC, RURP650CC, RURP660CC
Electrical Specifications (per leg) TC = +25oC, Unless Otherwise Specified
LIMITS
RURP640CC
RURP650CC
RURP660CC
SYMBOL
TEST CONDITION
MIN TYP MAX MIN TYP MAX MIN TYP MAX UNITS
VF
IF = 6A, TC = +25oC
-
IF = 6A, TC = +150oC
-
IR
VR = 400V, TC = +25oC
-
VR = 500V, TC = +25oC
-
VR = 600V, TC = +25oC
-
IR
VR = 400V, TC = +150oC
-
VR = 500V, TC = +150oC
-
VR = 600V, TC = +150oC
-
-
1.5
-
-
1.2
-
-
100
-
-
-
-
-
-
-
-
500
-
-
-
-
-
-
-
-
1.5
-
-
1.2
-
-
-
-
-
100
-
-
-
-
-
-
-
-
500
-
-
-
-
-
1.5
V
-
1.2
V
-
-
µA
-
-
µA
-
100
µA
-
-
µA
-
-
µA
-
500
µA
tRR
IF = 1A, dIF/dt = 200A/µs
-
-
55
-
-
55
-
-
55
ns
IF = 6A, dIF/dt = 200A/µs
-
-
60
-
-
60
-
-
60
ns
tA
IF = 6A, dIF/dt = 200A/µs
-
28
-
-
28
-
-
28
-
ns
tB
IF = 6A, dIF/dt = 200A/µs
-
16
-
-
16
-
-
16
-
ns
QRR
IF = 6A, dIF/dt = 200A/µs
-
150
-
-
150
-
-
150
-
nC
CJ
RθJC
VR = 10V, IF = 0A
-
25
-
-
-
3
-
25
-
-
-
3
-
25
-
pF
-
-
3
oC/W
DEFINITIONS
VF = Instantaneous forward voltage (pw = 300µs, D = 2%).
IR = Instantaneous reverse current.
tRR = Reverse recovery time (See Figure 2), summation of tA + tB.
tA = Time to reach peak reverse current (See Figure 2).
tB = Time from peak IRM to projected zero crossing of IRM based on a straight line from peak IRM through 25% of IRM (See Figure 2).
QRR = Reverse recovery charge.
CJ = Junction Capacitance.
RθJC = Thermal resistance junction to case.
EAVL = Controlled avalanche energy. (See Figures 10 and 11).
pw = pulse width.
D = duty cycle.
V1 AMPLITUDE CONTROLS IF
V2 AMPLITUDE CONTROLS dIF/dt
L1 = SELF INDUCTANCE OF
R4 + LLOOP
R1
+V1
0
t2
t1
Q1
R2
0
-V2
t3
Q3
R3
+V3
Q2
t1 ≥ 5tA(MAX)
t2 > tRR
t3 > 0
L1 ≤ tA(MIN)
R4
10
LLOOP
DUT
Q4
C1
R4
-V4
FIGURE 1. tRR TEST CIRCUIT
dIF
IF
dt
0
tRR
tA
tB
0.25 IRM
IRM
VR
VRM
FIGURE 2. tRR WAVEFORMS AND DEFINITIONS
6-56