NJU7670
■ TERMINAL DESCRIPTION
No.
SYMBOL
FUNCTION
1
C1+
Charge Pump Capacitor 1(+) Connecting Terminal
2
C1-
Charge Pump Capacitor 1(-) Connecting Terminal
3
C2+
Charge Pump Capacitor 2(+) Connecting Terminal
4
C2-
Charge Pump Capacitor 2(-) Connecting Terminal
5
NC
Non Connection
6
NC
Non Connection
7
VIN
Power Supply Terminal (-)
8
VOUT
Voltage Output Terminal
9
Vreg
Voltage Regulator Output Terminal
10
RV
Voltage Regulator Adjustment Terminal
11
Poff
Vreg Output ON/OFF Control Terminal
12
NC
Non Connection
13
NC
Non Connection
14
VDD
Power Supply Terminal (+)
■ FUNCTIONAL DESCRIPTION
(1) Voltage Converter
The voltage converter generates double or triple voltage against VIN.
VDD= 0V
VIN=-5V
VOUT=3・VIN=-15V
(2) Voltage Reference Circuit
The voltage reference circuit is generating the reference voltage for a voltage regulator.
(3) Voltage Regulator
The voltage regurator output stabilized voltage which regulated by using the external resistor against double or
triple voltage of the input voltage.
(3-1) Output-OFF Function
As this circuit incorporated output-off function, the voltage regulator output (ON/OFF) is performed by
the signal come from system.
VDD
Voltage
Poff
Regulator RV
Vreg
● ON/OFF Control for Vreg Terminal
Control signal
RRV=100kΩ~1MΩ
Poff Level
"H" (Connect to VDD)
"L" (Connect to VIN)
Vreg Output
ON
OFF
-2-
Ver.2011-02-03