Princeton Technology Corp.
Infrared Remote Control Transmitter
Tel: 886-2-29162151
Fax: 886-2-29174598
URL: http://www.princeton.com.tw
PT2560
Input
KO Lines
Custom Codes
CS KO0 KO1 KO2 KO3 KO4 C0 C1 C2 C3 C4 C5 C6 C7
0 0 0 0 0 0/1 0 0
*
*
1 0 0 0 0 0/1 0 0
*
*
0 1 0 0 0 0/1 0 0
*
*
*
1 1 0 0 0 0/1 0 0
*
*
0 0 1 0 0 0/1 0 0
*
*
*
1 0 1 0 0 0/1 0 0
*
*
*
0 1 1 0 0 0/1 0 0
*
*
*
*
1 1 1 0 0 0/1 0 0
*
*
0 0 0 1 0 0/1 0 0
*
*
*
1 0 0 1 0 0/1 0 0
*
*
*
0 1 0 1 0 0/1 0 0
*
*
*
*
1 1 0 1 0 0/1 0 0
*
*
*
0 0 1 1 0 0/1 0 0
*
*
*
*
1 0 1 1 0 0/1 0 0
*
*
*
*
0 1 1 1 0 0/1 0 0
*
*
*
*
*
1 1 1 1 0 0/1 0 0
*
* 0 0 0 0 1 0/1 0 0
*
*
* 1 0 0 0 1 0/1 0 0
*
*
* 0 1 0 0 1 0/1 0 0
*
*
*
* 1 1 0 0 1 0/1 0 0
*
*
* 0 0 1 0 1 0/1 0 0
*
*
*
* 1 0 1 0 1 0/1 0 0
*
*
*
* 0 1 1 0 1 0/1 0 0
*
*
*
*
* 1 1 1 0 1 0/1 0 0
*
*
* 0 0 0 1 1 0/1 0 0
*
*
*
* 1 0 0 1 1 0/1 0 0
*
*
*
* 0 1 0 1 1 0/1 0 0
*
*
*
*
* 1 1 0 1 1 0/1 0 0
*
*
*
* 0 0 1 1 1 0/1 0 0
*
*
*
*
* 1 0 1 1 1 0/1 0 0
*
*
*
*
* 0 1 1 1 1 0/1 0 0
*
*
*
*
*
* 1 1 1 1 1 0/1 0 0
Note: * = CS is connected to the respective KO Line.
For PT2650-001, Custom Code Bit 5 (C5) = “0”.
For PT2560-003, Custom Code Bit 5 (C5) = “1”.
PT2560 v 2.0
Page 9
Written July 1998