Si3035
Table 5. AC Characteristics
(VA = Charge Pump, VD = +3.3 V ± 0.3 V, TA = 0 to 70°C for K-Grade)
Parameter
Sample Rate1
PLL1 Output Clock Frequency
Transmit Frequency Response
Symbol
Test Condition
Min
Fs
Fs = FPLL2/5120
7.2
FPLL1 FPLL1 = FMCLK " M1/N1 36
Low –3 dB corner
—
Typ Max Unit
— 11.025 kHz
—
58 MHz
16
—
Hz
Receive Frequency Response
Low –3 dB corner
—
16
Transmit Full Scale Level2 (0 dB gain)
VTX
—
Receive Full Scale Level 2,3 (0 dB gain) VRX
—
Dynamic Range4
DR VIN = 1 kHz, –3 dBFS 80
0.98
0.98
86
Dynamic Range5
DR VIN = 1 kHz, –3 dBFS —
84
Total Harmonic Distortion6
THD VIN = 1 kHz, –3 dBFS —
–84
—
Hz
—
VPEAK
—
VPEAK
—
dB
—
dB
—
dB
Dynamic Range (call progress AOUT)
THD (call progress AOUT)
AOUT Full Scale Level
AOUT Output Impedance
Mute Level (call progress AOUT)
DRAO
THDAO
VIN = 1 kHz
VIN = 1 kHz
60
—
—
dB
—
1.0
—
%
— 0.75 VD —
VPP
—
10
—
kΩ
–90
—
—
dB
Dynamic Range (caller ID mode)
DRCID VIN = 1 kHz, –13 dBFS —
60
—
dB
Caller ID Full Scale Level (0 dB gain)2
VCID
—
0.8
—
VPEAK
Notes:
1. See Figure 23 on page 22.
2. Parameter measured at TIP and RING of Figure 16 on page 15.
3. Receive Full Scale Level will produce – 0.9 dBFS at SDO.
4. DR = 3 dB + 20 log (RMS signal/RMS noise). Applies to both the transmit and receive paths. Measurement bandwidth
is 300 to 3400 Hz. Sample Rate = 9.6 kHz, Loop Current = 40 mA.
5. DR = 3 dB + 20 log (RMS signal/RMS noise). Applies to both the transmit and receive paths. Measurement bandwidth
is 15 to 3400 Hz. Sample Rate = 9.6 kHz, Loop Current = 40 mA.
6. THD = 20 log (RMS distortion/RMS signal). Applies to both the transmit and receive paths.
Sample Rate = 9.6 kHz, Loop Current = 40 mA.
6