Bit Pattern
Read Command
(D/C=0, R/W(WR)=1, E(RD)=0)
D7D6D5D4D3D2D1D0
Status Register Read
(Data Read Back from the
driver)
Comment
D7=0: indicates an internal operation is completed.
D7=1: indicates an internal operation is in progress.
D6=0: indicates reverse segment mapping with column address
D6=1: indicates normal segment mapping with column address
D5=0: indicates the display is ON
D5=1: indicates the display is OFF
D4=0: initialization is not in progress
D4=1: initialization is in progress after RES or software reset
D3D2D1D0 = 1010, these 4-bit is fixed to 1010 which could be used
to identify as Solomon Systech Device.
EXTENDED COMMAND TABLE
Bit Pattern
Command
10101000
00X5X4X3X2X1X0
10101001
X7X6X5X4X3X2X1X0
X5X4X3X2X1X0: Set Multiplex Ratio
X1X0: Set Bias Ratio
Comment
To select multiplex ratio N from 2 to 65 [Included Icon Line].
N = X5X4X3X2X1X0 + 2, eg. N = 111111b + 2 = 65 (POR)
X1X0 = 00: 1/8, 1/6
X1X0 = 01: 1/6, 1/5
X1X0 = 10: 1/9, 1/7 (POR)
X1X0 = 11: Prohibited
X4X3X2: Set TC Value
X4X3X2 = 000: -0.01%/C (TC0, POR)
X4X3X2 = 010: -0.10%/C (TC2)
X4X3X2 = 100: -0.18%/C (TC4)
X4X3X2 = 111: -0.25%/C (TC7)
X4X3X2 = 001, 011, 101, 110: Reserved
1010101X0
11010010
0X6X500010
11010011
00X5X4X3X2X1X0
X7X6X5: Modify Osc. Freq.
Increase the value of X7X6X5 will increase the oscillator frequency
and vice versa. This command is not recommended to be used.
X7X6X5 = 011(POR)
X0: Set 1/4 Bias Ratio
X0 = 0: use Normal Setting (POR)
X0 = 1: fixed at 1/4 Bias
X6X5: Set Total Frame Phases
The On/Off of the Static Icon is given by 3 phases/1 phase overlap-
ping of the M and MSTAT signals. This command set how many
phases of dividing the M/MSTAT signals for each frame.
The more the phases, the less the overlapping and thus the lower
the effective driving voltage.
X6X5 = 00: 3 phases
X6X5 = 01: 5 phases
X6X5 = 10: 7 phases (POR)
X6X5 = 11: 16 phases
X5X4X3X2X1X0: Set Display Offset
After POR, X5X4X3X2X1X0 = 0
(for mux ratio has been After setting mux ratio less than 64, data will be displayed at Center
set less than 64 only) of matrix. See Table 1.
To move display towards Row 0 by L, X5X4X3X2X1X0 = L
To move display away from Row 0 by L, X5X4X3X2X1X0 = 64-L
Note: max. value of L = (64 - display mux)/2
Note: Patterns other than that given in Command Table and Extended Command Table are prohibited to enter to the chip
as a command. Otherwise, unexpected result will occurs.