TC9400/9401/9402
TC940X ELECTRICAL SPECIFICATIONS (CONTINUED)
Electrical Characteristics: VDD = +5V, VSS = -5V, VGND = 0V, VREF = -5V, RBIAS = 100kΩ, Full Scale = 10kHz, unless otherwise
specified. TA = +25°C, unless temperature range is specified (-40°C to +85°C for E device, 0°C to +70°C for C device).
Parameter
Min Typ Max Min Typ Max Min Typ Max Units
Test Conditions
Frequency Input
Positive Excursion 0.4
—
VDD 0.4
— VDD 0.4
—
VDD
Negative Excursion -0.4
-2 -0.4 —
-2 -0.4 —
-2
Minimum Positive
Pulse Width
(Note 8)
Minimum Negative
Pulse Width
(Note 8)
Input Impedance
Analog Outputs
Output Voltage
(Note 9)
—
5
—
— 0.5 —
—
10
—
TC9400
— VDD – 1 —
—
5
—
—
0.5
—
—
10
—
TC9401
— VDD – 1 —
—
5
—
— 0.5
—
—
10
TC9402
— VDD – 1 —
Output Loading
2
—
—
2
—
—2
—
—
Supply Current
IDD Quiescent
(Note 10)
TC9400
— 1.5
6
TC9401
—
1.5
6
TC9402
—
3
10
ISS Quiescent
(Note 10)
— -1.5 -6
-1.5 -6 —
-3
-10
VDD Supply
VSS Supply
4
— 7.5 4
— 7.5 4
—
7.5
-4
— -7.5 -4
— -7.5 -4
—
-7.5
Reference Voltage
VREF – VSS
-2.5 —
— -2.5 —
— -2.5 —
—
Note
1: Full temperature range; not tested.
2: IIN = 0.
3: Full temperature range, IOUT = 10mA.
4: IOUT = 10µA.
5: Threshold Detect = 5V, Amp Out = 0V, full temperature range.
6: 10Hz to 100kHz; not tested.
7: 5µsec minimum positive pulse width and 0.5µsec minimum negative pulse width.
8: tR = tF = 20nsec.
9: RL ≥ 2kΩ, tested @ 10kΩ.
10: Full temperature range, VIN = -0.1V.
V
V
µsec
Voltage Required to
Turn Threshold
Detector On
Voltage Required to
Turn Threshold
Detector Off
Time between
Threshold Crossings
µsec
Time Between
Threshold Crossings
MΩ
V
Voltage Range of Op
Amp Output for Speci-
fied Non-Linearity
kΩ Resistive Loading at
Output of Op Amp
mA Current Required from
Positive Supply During
Operation
mA Current Required from
Negative Supply
During Operation
V
Operating Range of
Positive Supply
V
Operating Range of
Negative Supply
V
Range of Voltage
Reference Input
© 2002 Microchip Technology Inc.