Parameter definitions
TSC1021
5.5
Output voltage accuracy
The output voltage accuracy is the difference between the actual output voltage and the
theoretical output voltage. Ideally, the current sensing output voltage should be equal to the
input differential voltage multiplied by the theoretical gain, as in the following formula.
Vout-th = Av ⋅ Vsense
The actual value is very slightly different, mainly due to the effects of:
● the input offset voltage Vos,
● the non-linearity,
● the voltage saturation of VOL and VOH.
The output voltage accuracy, expressed as a percentage, can be calculated with the
following formula.
ΔVout = a----b----s---(---V----o--A-u---v-t---–-⋅---(---A-V---v-s---e-⋅---n---s-V--e--s---e---n----s---e---)---)
with Av = 20 V/V for TSC1021A and Av = 50 V/V for TSC1021B.
8/12
Doc ID 17857 Rev 1