Small, Low leakage current type (1-Stage filter)
EAM series
Ordering information
EAM -10 -000 -O
1
2
3
4
1Model Name
R
2Rated Current
3Line to ground capacitor code:See table 1.1.
table1.1 Line to ground capacitor code
Code
000
101
221
331
471
Leakage Current
(Input 125/250V 60Hz)
5 A/ 10 A max
12.5 A/ 25 A max
25 A/ 50 A max
37.5 A/ 75 A max
50 A/100 A max
Line to ground
capacitor
(nominal value)
Not Provided
100pF
220pF
330pF
470pF
* When the line to ground capacitor code is
different, the attenuation characteristic is
different.
4 Options
D :DIN rail installation type
* The dimensions change when the option is set.
Refer to External view.
The terminal cover is retracted inside the unit
DIN rail installation type is option
Features of EAM series
Small, Low leakage current type(1-Stage filter)
- Single Phase 250 VAC
-Small-size
-Quick and easy push-down terminal
Just connect the wires,push-down and tighten
the screws with a screwdriver
Specifications
No. Items
EAM-03-000 EAM-06-000 EAM-10-000 EAM-16-000 EAM-20-000 EAM-30-000
1 Rated Voltage[V]
AC 1f 250 / DC250
2 Rated Current[A]
3
6
10
16
20
30
3 Test Voltage (Terminal-Mounting Plate)
2,500 VAC (Cutoff Current = 20mA), 1minute at room temperature and humidity
4 Isolation Resistance (Terminal-Mounting Plate) 500 VDC 500MW min at room temperature and humidity
5 Leakage current 125/250V 60Hz
5 A/10 A max
6 DC resistance
180mW max 110mW max 40mW max 20mW max 10mW max 6mW max
7 Safety agency approval temperatures
-25 to +85C (Refer to Derating Curve)
8 Operating temperature
-40 to +85C (Refer to Derating Curve)
9 Operating humidity
20 to 95%RH (Non condensing)
10 Storage temperature/humidity
-40 to +85C/20 to 95%RH (Non condensing)
11 Vibration
10 to 55Hz, 19.6m/s2 (2G), 3min. Period, 1hour each X, Y and Z axis
12 Impact
196.1m/s2 (20G), 11ms Once each X, Y and Z axis
13 Safety agency approvals
UL1283, CSA C22.2 No.8 (C-UL), DIN EN60939 VDE0565 Teil3-1, ENEC (At only AC input)
14 Case size (without projection) /Weight
39X30X85 mm [1.54X1.18X3.35 inches] (WXHXD) /170g max (Option : -D refer to external view)
Circuit Diagram
Case
1
LINE
2
3
CY
LOAD
CY
4
CY : Line to ground capacitor : Mounting Plate
Derating Curve
100
80
60
40
20
0
-40 -30 -20 40 50 55 60 70 80 90
Ambient Temperature [C]
EA/ES-2