Eighth Brick DC/DC Converters
30 Amps
KHE030 Series
XPiQ inc.
Intelligent Design Quality Product
•
Low Voltage Outputs
•
Y 38% Less Board Space than 1/4 Brick
AR with the same Pinout
IN •
ELIM High Efficiency 89% for 3.3 V
PR 2003 •
International Safety Approvals
Q3 •
Fixed Switching Frequency
•
Low 0.417” Profile
Specification
Input
Input Voltage Range •
Input Current
•
Input Reflected
•
Ripple Current
Remote On/Off
•
Input Reverse
•
Voltage Protection
Output
Output Voltage
•
Output Voltage
•
Adjustment
Minimum Load
•
Line Regulation
•
Load Regulation
•
Setpoint Accuracy •
Ripple & Noise
•
Transient Response •
Temperature
•
Coefficient
Remote Sense
•
Overvoltage
•
Protection
Overcurrent
•
Protection
Overtemperature
•
Protection
36-75 VDC
2.40 A max at 36 VDC
1.20 A max at 75 VDC
25 mA
Shorted to -Vin (Logic Low) = ON
Open (Logic High) = OFF
Positive logic is available
External components required
1.2 VDC to 5.0 VDC
±10%
0 minimum load required
0.1% (36-75 VDC; full load)
0.2% (no load to full load, 48 V input)
±1% maximum
70 mV pk-pk maximum
3% max deviation, 100 µs recovery
time for a 25% load change
0.01%/°C
General
Efficiency
•
Isolation Voltage
•
Switching Frequency •
Package Style
•
MTBF
•
Size
•
Weight
•
89% for 3.3 Vout, See Chart
1500 VDC Input to Output
260 kHz/±30 kHz
Open frame
1,000,000 hours per Bellcore
0.896” x 0.417” x 2.30”
15 grams
Environmental
Operating
•
Temperature
with 300 LFM
Cooling
•
Humidity
•
Storage Temperature •
-40 °C to +85 °C ambient
see derating chart
Full power to +70 °C
Convection or forced air
5-95% RH non-condensing
-55 °C to 125 °C
Safety
Safety Approvals
EMI/EMC
• UL60950, TUV (per EN60950) cUL
CE marked
• Bellcore TSYNWT 1089 with
external filter
Compensates for up to 10% Vout drop
120-135%, recycle input to reset
115-150%, constant current with
auto recovery
Shutdown at +125 °C with auto restart
* Preliminary datasheet - see website for current specs
•
www.XPiQ.com
PH: 508 429.9883
•
FAX: 800 226.2100
Email: sales@xpiq.com