TP-UART-IC
Each L_Data-request is transmitted completely to the host controller. If TP - UART is polling
master the complete polling frame is transmitted to the host controller and regardless of
whether a collision is detected while sending the polling frame, or not. In case TP - UART is
polling slave just the control byte out of L_PollData-request is transmitted to the host
controller.
3.2.3.2.2 Acknowledge-Services
Acknowledge-Services are just transmitted to the host controller in busmonitor mode.
The short acknowledgment frame format consists of 15 Tbit (1 Tbit = 1/9600 s) idle time
followed by a single character which is used to acknowledge a L_Data.req frame. The
following figure shows the corresponding codes of the short acknowledgment.
Octet 0
Short ACK
87654321
1 1 0 0 1 1 0 0 ACK
0 0 0 0 1 1 0 0 NACK
1 1 0 0 0 0 0 0 BUSY
3.2.3.2.3 TP-UART-Control-Services
The TP-UART-Control-Services are services which exist only on this interface. They have to
reset the communication or to inform the host controller about the actual state.
3.2.3.2.3.1 TP-UART-Reset.indication-Service
The Reset.indication-Service is sent after each reset (e.g. TP_UART_Reset.requ).
TP-UART-Control Field
76543210
00000011
3.2.3.2.3.2 TP-UART-State.indication/response-Service
The TP-UART-State.response-Service is sent if an U_State.request-Service was received
from the host controller. In case of a slave collision, receive error, checksum error or
protocol error the TP-UART-IC sends a State.indication-Service.
TP-UART-Control Field
76543210
SC RE TE PE TW 1 1 1
SC = Slave Collision
RE = Receive Error (checksum, parity or bit error)
TE = Transmitter Error (send 0 receive 1)
PE = Protocol Error (e.g. illegal control byte)
TW = Temperature Warning1)
1)After a temperature warning was received, a second must at least be maintained until the next
telegram is sent.
The reproduction, transmission or use of this document or it‘s contents is not permitted without express written authority. All
rights, including right created by patent grant or registration of a utility model or design, are reserved. Technical changes
reserved.
25.15.10.41.33a
25.10.01
page 20

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]