MITSUBISHI <INTELLIGENT POWER MODULES>
PM100CSD120
FLAT-BASE TYPE
INSULATED PACKAGE
CONTROL PART
Symbol
Parameter
Test Condition
Limits
Min.
Typ.
Max. Unit
ID
Circuit Current
VD = 15V, VCIN = 15V
VN1-VNC
—
45
62
mA
VXP1-VXPC
—
15
20
Vth(on)
Vth(off)
Input ON Threshold Voltage Applied between : UP-VUPC, VP-VVPC, WP-VWPC
Input OFF Threshold Voltage
UN • VN • WN-VNC
1.2
1.5
1.8
V
1.7
2.0
2.3
OC
Over Current Trip Level
VD = 15V
Tj = 25°C
(Fig. 5,6) Tj = 125°C
228
345
—
145
—
—
A
SC
Short Circuit Trip Level
–20≤ Tj ≤ 125°C, VD = 15V
(Fig. 5,6) —
340
—
A
toff(OC) Over Current Delay Time
VD = 15V
(Fig. 5,6) —
10
—
µs
OT
Base-plate
Trip level
OTr
Over Temperature Protection Temperature detection, VD = 15V
Reset level
111
—
118
100
125
—
°C
UV
Supply Circuit Under-Voltage –20 ≤ Tj ≤ 125°C
UVr
Protection
Trip level
Reset level
11.5
12.0
12.5
—
12.5
—
V
IFO(H)
IFO(L)
Fault Output Current
VD = 15V, VFO = 15V
—
(Note-3)
—
—
0.01
mA
10
15
tFO
Minimum Fault Output Pulse VD = 15V
Width
(Note-3) 1.0
1.8
—
ms
(Note-3) Fault output is given only when the internal OC, SC, OT & UV protection.
Fault output of OC, SC and UV protection operate by upper and lower arms.
Fault output of OT protection operate by lower arm.
Fault output of OC, SC protection given pulse.
Fault output of OT, UV protection given pulse while over level.
MECHANICAL RATINGS AND CHARACTERISTICS
Symbol
—
—
—
Parameter
Mounting torque
Mounting torque
Weight
Main terminal
Mounting part
Test Condition
—
Limits
Min.
Typ.
Unit
Max.
screw : M5
2.5
3.0
3.5 N • m
screw : M5
2.5
3.0
3.5 N • m
—
920
—
g
RECOMMENDED CONDITIONS FOR USE
Symbol
Parameter
VCC
Supply Voltage
VD
Control Supply Voltage
VCIN(on)
VCIN(off)
Input ON Voltage
Input OFF Voltage
fPWM
PWM Input Frequency
tdead
Arm Shoot-through
Blocking Time
Test Condition
Recommended value
Unit
Applied across P-N terminals
≤ 800
V
Applied between : VUP1-VUPC, VVP1-VVPC
VWP1-VWPC, VN1-VNC
(Note-4)
15 ± 1.5
V
Applied between : UP-VUPC, VP-VVPC, WP-VWPC
UN • VN • WN-VNC
≤ 0.8
≥ 4.0
V
Using Application Circuit input signal of IPM, 3φ
sinusoidal PWM VVVF inverter
(Fig. 8)
≤ 20
kHz
For IPM’s each input signals
(Fig. 7)
≥ 3.0
µs
(Note-4) Allowable Ripple rating of Control Voltage : dv/dt ≤ ±5V/µs, 2Vp-p
Jul. 2005