MTD502EF(128PQFP) Jumper Setting Table After Power On Reset
Pin No. IO
101
IO
Setting Function
Descriptions
P0_Bkoff_4 Enable Jumper setting function after power on reset.
-external pull_high = 1, means Port 0 MAC backoff engine is using
limit_4 modified method.
-external pull_low = 0, means Port 0 MAC backoff engine is using
specification defined method.
-external floating : default is 0.
102
IO
DeviceID[4]
Jumper setting function after power on reset.
-external pull_high = 1.
-external pull_low = 0.
-external floating : default is 0.
104
IO
DeviceID[3]
Jumper setting function after power on reset.
-external pull_high = 1.
-external pull_low = 0.
-external floating : default is 0.
106
IO
DeviceID[2]
Jumper setting function after power on reset.
-external pull_high = 1.
-external pull_low = 0.
-external floating : default is 0.
107
IO
DeviceID[1]
Jumper setting function after power on reset.
-external pull_high = 1.
-external pull_low = 0.
-external floating : default is 0.
108
IO
DeviceID[0]
Jumper setting function after power on reset.
-external pull_high = 1.
-external pull_low = 0.
-external floating : default is 0.
109
IO P1_CRCchk Disable Jumper setting function after power on reset.
-external pull_high = 1, means Port1 CRC check and drop function
is disabled.
-external pull_low = 0, means Port1 CRC check and drop function
is enabled.
-external floating : default is 0.
9/20