POWERLINE - DC/DC-Converter
G-Series, 40W, 1.6 kV Isolation, 2:1 Wide Input Range (Single, Dual & Triple Output)
Specifications continued (typical at nominal input and 25°C unless otherwise noted)
Operating Temperature Range
-40°C to +85°C (with derating)
Maximum Case Temperature
+100°C
Storage Temperature Range
-55°C to +105°C
Thermal Impedance
Natural convection
9.2°C/Watt
Thermal Shock
MIL-STD-810D
Vibration
10-55Hz, 2G, 3 Min. Period, 30 Min. along X, Y and Z
Relative Humidity
5% to 95% RH
Conducted Emissions
EN55022
Level A
Radiated Emissions
Conducted Immunity
EN55022
EN61000-4-6
Level A
Perf. Criteria 2
Radiated Immunity
EN61000-4-3
Perf. Criteria 2
Surge
Fast Transient
EN61000-4-5
EN61000-4-4
Perf. Criteria 2
Perf. Criteria 2
ESD Air
EN61000-4-2
Perf. Criteria 2
Notes:
1. The RP40 G-series requires a minimum of 10% loading on the output to maintain specified
regulation. Operation under no-load condition will not damage these devices, however
they may not meet all listed specification.
2. Simulated source impedance of 12uH. 12uH inductor in series with +Vin.
3. The ON/OFF control pin voltage is referenced to negative input.
4. Maximum value at nominal input voltage and full load.
5. Typical value at nominal input voltage and full load.
6. It will compensate for up to 0.5V line drop voltage between converter and load.
If remote sense is not being used, the +sense should be connected to its corresponding
+OUTPUT and likewise the –sense should be connected to its corresponding –OUTPUT.
Package Style and Pinning (mm)
50.80
29.20
10.20
5.10
3
21
50.80
Bottom
View
10.20
dia.
1.0
45.70
98
76
54
2.5
7.6
5.6
15.20
5.1
20.30
12.70
Pin Connections
Pin # Single
Dual
Triple
1
+Vin
+Vin
+Vin
2
-Vin
-Vin
-Vin
3
Ctrl
Ctrl
Ctrl
4
NC
3.3V
+Aux
5
-Sense
3.3V
Common
(see note 6)
RTN
6
+Sense
NC
–Aux
(see note 6)
7
+Vout
NC
+Vout
8
–Vout
5V
–Vout
9
Trim
5V
NC
RTN
Pin Pitch Tolerance ±0.35 mm
PO 70
August 2002
www.recom-international.com