DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

PMB8510P Ver la hoja de datos (PDF) - Ericsson

Número de pieza
componentes Descripción
Fabricante
PMB8510P Datasheet PDF : 32 Pages
First Prev 21 22 23 24 25 26 27 28 29 30 Next Last
EMC Specification
The conducted EMI measurement was performed using a
regulator placed directly on the test bench. The fundamental
switching frequency for PMB 8000 is 300 kHz. The measure-
ment below has been performed with Vin = 12 V, Vout = 5 V
and max load. Input filter 4 x 4.7 mF and output filter 2 x 150
mF was used during the measurement.
Layout Recommendation
The radiated EMI performance of the DC/DC regulator will
be optimised by including a ground plane in the PCB area
under the DC/DC regulator. This approach will return switch-
ing noise to ground as directly as possible, with improve-
ments to both emissions and susceptibility.
Conducted EMI Input terminal value (typ)
Level [dBµA]
100
80
60
40
20
0
-10 150k 300k 500k
1M
2M 3M 5M 7M 10M
30M
Frequency [Hz]
MES EPM_PMB16A_1_pre PK
PMB 8818.
&.$3FDJWFS
$PNQVUFS
Output ripple and noise
The circuit below has been used for the ripple and noise
measurements on the PMB 8000 Series DC/DC regulators.
7PVU
4FOTF
5SJN
-PX&431PMZNFS
$BQBDJUPS
YM
-PBE
(/%
$POEVDUPSGSPN7PVUUPDBQBDJUPSTNN<JO>
Output ripple and noise test setup
#/$
$POOFDUPS
UP4DPQF
¬'
%$
1PXFS
4PVSDF

DN
1SJOUFE$JSDVU#PBSE
1PXFS
3FHVMBUPS
DN
3FTJTUJWF
-PBE
Test set up.
PMB 8818T P Datasheet
27
EN/LZT 146 066 R2A © Ericsson Power Modules, April 2007

Share Link: 