Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
PM300CVA060
Intellimod™ Module
Three Phase IGBT Inverter Output
300 Amperes/600 Volts
Electrical and Mechanical Characteristics, Tj = 25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Typ. Max. Units
Control Sector
Short Circuit Trip Level
Short Circuit Current Delay Time
Over Temperature Protection
(VD = 15V)
Supply Circuit Under Voltage Protection
(-20°C ≤ Tj ≤ 125°C)
Circuit Current
Input ON Threshold Voltage
Input OFF Threshold Voltage
Fault Output Current
Minimum Fault Output Pulse Width
SC
toff(SC)
OT
OTr
UV
UVr
ID
VCIN(on)
VCIN(off)
IFO(H)
IFO(L)
tFO
-20°C ≤ Tj ≤ 125°C, VD = 15V
VD = 15V
Trip Level
Reset Level
Trip Level
Reset Level
VD = 15V, VCIN = 15V, VN1-VNC
VD = 15V, VCIN = 15V, VXP1-VXPC
Applied between UP-VUPC, VP-VVPC,
WP-VWPC, UN, VN, WN-VNC
VD = 15V, VFO = 15V
VD = 15V, VFO = 15V
VD = 15V
396
—
100
85
11.5
—
—
—
1.2
1.7
—
—
1.0
—
10
110
95
12.0
12.5
52
17
1.5
2.0
—
10
1.8
— Amperes
—
µS
120
°C
105
°C
12.5 Volts
—
Volts
72
mA
24
mA
1.8
Volts
2.3
Volts
0.01
mA
15
mA
—
mS
403