EN29F080
Figure 7. Program Operation Timings
Addresses
Program Command Sequence (last 2 cycles)
tWC
tAS
tAH
0x555
PA
CE#
OE#
tGHWL
tWP
tCH
Program Command Sequence (last 2 cycles)
PA
PA
WE#
Data
tCS
OxA0
tDS
RY/BY#
tVCS
tWPH
tDH
VCC
PD
tBUSY
tWHWH1
Status
DOUT
tRB
Notes:
1. PA=Program Address, PD=Program Data, DOUT is the true data at the program address.
2. VCC shown in order to illustrate tVCS measurement references. It cannot occur as shown during a valid
command sequence.
4800 Great America Parkway, Suite 202
30
Santa Clara, CA 95054
Tel: 408-235-8680
Fax: 408-235-8685