Chart-A1 Vertical Direction Sequence Chart
MODE
Draft → Frame (or double speed) → Draft
Applicable CCD image sensor
• ICX282
VD
V1A
V1B
V1C
V2
V3A
V3B
V3C
V4
SUB
Mechanical
shutter
Exposure time
CCD OUT
MODE
A
0
B
A
0
C
B
0
D
C
0
Close
E
0
E
3
∗ This chart is a drive timing chart example of electronic shutter normal operation.
∗ Data exposed at D includes the blooming component. For details, see the CCD image sensor data sheet.
∗ The CXD2498R does not generate the pulse to control mechanical shutter operation.
∗ The switching timing of drive mode and electronic shutter data are not the same.
E
3
Open
F
F
0
0