AD7147
CDC CONVERSION
SEQUENCE
(INTERNAL)
PROXIMITY
DETECTION
(INTERNAL)
USER APPROACHES
SENSOR
USER LEAVES
SENSOR AREA
16
tCALDIS
MEASURED CDC VALUE > STORED AMBIENT
BY PROXIMITY_RECAL _LVL
tRECAL
30
70
tCONV_FP
CALIBRATION
(INTERNAL)
CALIBRATION DISABLED
RECALIBRATION TIMEOUT
CALIBRATION ENABLED
RECALIBRATION
COUNTER
(INTERNAL)
tRECAL_TIMEOUT
NOTES
1. SEQUENCE CONVERSION TIME tCONV_FP (SEE TABLE 10).
2. tCALDIS = tCONV_FP × FP_PROXIMITY_CNT × 16.
3. tRECAL_TIMEOUT = tCONV_FP × FP_PROXIMITY_RECAL.
4. tRECAL = 2 × tCONV_FP.
Figure 31. Example of Full Power Mode Proximity Detection with Forced Recalibration (FP_PROXIMITY_CNT = 1 and FP_PROXIMITY_RECAL = 40)
CDC CONVERSION
SEQUENCE
(INTERNAL)
PROXIMITY
DETECTION
(INTERNAL)
USER APPROACHES
SENSOR
USER LEAVES
SENSOR AREA
16
tCALDIS
MEASURED CDC VALUE > STORED AMBIENT
BY PROXIMITY_RECAL _LVL
tRECAL
30
70
tCONV_LP
CALIBRATION
(INTERNAL)
RECALIBRATION
(INTERNAL)
CALIBRATION DISABLED
RECALIBRATION TIMEOUT
tRECAL_TIMEOUT
CALIBRATION ENABLED
NOTES
1. SEQUENCE CONVERSION TIME tCONV_LP = tCONV_FP + LP_CONV_DELAY.
2. tCALDIS = tCONV_LP × LP_PROXIMITY_CNT × 4.
3. tRECAL_TIMEOUT = tCONV_LP × LP_PROXIMITY_RECAL.
4. tRECAL = 2 × tCONV_LP.
Figure 32. Example of Low Power Mode Proximity Detection with Forced Recalibration (LP_PROXIMITY_CNT = 4 and LP_PROXIMITY_RECAL = 40)
Rev. 0 | Page 20 of 68