ADP199
ABSOLUTE MAXIMUM RATINGS
Table 2.
Parameter
VIN to GND
VOUT to GND
EN to GND
Continuous Drain Current
TA = 25°C
TA = 85°C
Continuous Diode Current
Storage Temperature Range
Operating Junction Temperature Range
Soldering Conditions
Rating
−0.3 V to +4.0 V
−0.3 V to VIN
−0.3 V to +4.0 V
±1000 mA
±700 mA
−50 mA
−65°C to +150°C
−40°C to +85°C
JEDEC J-STD-020
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
Table 3. Typical θJA and ΨJB Values
Package Type
θJA
4-Ball, 0.4 mm Pitch WLCSP 260
ESD CAUTION
Data Sheet
ΨJB
Unit
58
°C/W
Rev. A | Page 4 of 16