B32921 ... B32926
X2 / 305 VAC
Technical data
Standard version (A/B/T): B3292*A.... / B3292*B.... / B3292*T....
Miniaturized version (C/D): B3292*C.... / B3292*D.... (preferred types)
Max. operating temperature Top,max
Dissipation factor tan δ (in 10-3)
at 20 °C (upper limit values)
+125 °C (for CR ≤1 µF with A/B/T version)
+110 °C (for CR >1 µF or C/D version)
CR≤0.1 µF 0.1µF<CR ≤2.2 µF CR >2.2 µF
at 1 kHz 1.0
1.0
2.0
100 kHz 5.0
Insulation resistance Rins
CR≤0.33 µF CR>0.33 µF
or time constant τ = CR Rins
100 000 MΩ 30 000 s
at 20 °C, rel. humidity ≤ 65%
(minimum as-delivered values)
DC test voltage
2121 V, 2 s
Passive flammability category
B
to IEC 40 (CO) 752
Maximum continuous AC voltage VAC 310 V (50/60 Hz)
Rated AC voltage (IEC 60384-14) 305 V (50/60 Hz)
Maximum continuous DC voltage VDC
Operating AC voltage Vop at high
temperature
760 V (630 V for C/D version)
TA ≤ 110 °C
TA ≤ 110 °C
Vop = VAC
Vop = 1.25 VAC
110 °C <TA ≤ 125 °C Vop = VAC
(continuously)
(1000 h)
(1000 h) (only
for A/B/T version)
Damp heat test
56 days / 40 °C / 93% relative humidity
Limit values after damp heat test
Capacitance change ∆C/C
Dissipation factor change ∆ tan δ
Insulation resistance Rins
or time constant τ = CR Rins
≤ 5%
≤ 0.5 10-3 (at 1 kHz)
≤ 1.0 10-3 (at 10 kHz)
≥ 50% of minimum
as-delivered values
7