LC78630E
Note: 1. During a track check operation the TOFF pin goes high and the tracking loop is turned off. Therefore, feed motor forwarding is required.
2. When a track check in/out command is issued the function of the WRQ signal switches from the normal mode subcode Q standby monitor
function to the track check monitor function. This signal goes high when the track count is half completed, and goes low when the count
finishes. The control microprocessor should monitor this signal for a low level to determine when the track check completes.
3. If a track check clear command ($FF) is not issued, the track check operation will repeat. This can be used. For example, to skip over
20,000 tracks, issue a track check 199 code once, and then count the WRQ signal 100 times. This will count 20,000 tracks.
4. After performing a track check operation, use the TJ brake command to lock the pickup onto the track.
7. Sled output; Pin 30: SLD+, pin 31: SLD
Code
$B8
Command
SLED SET
RES = low
The SLED+ and SLEDoutputs can be set independently to one of four levels using this 2-byte command. Neither
SLED+ nor SLEDare output after a reset.
DATA BYTE + $B8
SLED OUTPUT SETTING
SLED+ and SLEDoutput is selected by the most significant bit in the data byte. The SLED output level is set by the
lower 3 bits. When SLED+ is set, SLEDis automatically set to VSS (SLED off). The inverse is also true.
d7
Output pin
0
SLED+
1
SLED
d2
d1
d0
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
Output level
VSS (SLED off)
0.25 VDD
0.5 VDD
0.75 VDD
VDD
8. Error flag output; Pin 61: EFLG, pin 66: FSX
No. 5121-18/33