LC78684E
Notes on PWB Pattern Design
x In an ideal design, power supply and ground lines will be provided separately for each system to minimize the influence of
shared impedances.
x Power supply and ground lines must be made as wide and as short as possible, and the impedance to high frequencies must
be made as low as possible. Decoupling capacitors (consisting of two capacitors: one about 0.01 to 1.0 µF and another about
100 to 220 µF) should be inserted between each power supply pin and ground. Note, however, that if this capacitance is too
large, it may result in latchup problems.
Other Notes
If you have any questions or if anything is even slightly unclear, please contact your SANYO sales or technical representative
during the design phase. This IC is a special-purpose device for use in CD players, and its specifications differ from those of
standard logic ICs and other general-purpose products. Also note that, depending on the application, failsafe measures and/or
system level debugging of the total system may be required as well.
Q Specifications of any and all SANYO products described or contained herein stipulate the performance,
characteristics, and functions of the described products in the independent state, and are not guarantees
of the performance, characteristics, and functions of the described products as mounted in the customer’s
products or equipment. To verify symptoms and states that cannot be evaluated in an independent
device, the customer should always evaluate and test devices mounted in the customer’s products or
equipment.
Q SANYO Electric Co., Ltd. strives to supply high-quality high-reliability products. However, any and all
semiconductor products fail with some probability. It is possible that these probabilistic failures could give
rise to accidents or events that could endanger human lives, that could give rise to smoke or fire, or that
could cause damage to other property. When designing equipment, adopt safety measures so that these
kinds of accidents or events cannot occur. Such measures include but are not limited to protective circuits
and error prevention circuits for safe design, redundant design, and structural design.
Q In the event that any or all SANYO products (including technical data, services) described or contained
herein are controlled under any of applicable local export control laws and regulations, such products
must not be exported without obtaining the export license from the authorities concerned in accordance
with the above law.
Q No part of this publication may be reproduced or transmitted in any form or by any means, electronic or
mechanical, including photocopying and recording, or any information storage or retrieval system, or
otherwise, without the prior written permission of SANYO Electric Co., Ltd.
Q Any and all information described or contained herein are subject to change without notice due to
product/technology improvement, etc. When designing equipment, refer to the “Delivery Specification” for
the SANYO product that you intend to use.
Q Information (including circuit diagrams and circuit parameters) herein is for example only; it is not
guaranteed for volume production. SANYO believes information herein is accurate and reliable, but no
guarantees are made or implied regarding its use or any infringements of intellectual property rights or
other rights of third parties.
This catalog provides information as of February, 2003. Specifications and information herein are subject to
change without notice.
No.7350-21/21