M41ST84Y, M41ST84W
Power-on Reset
The M41ST84Y/W continuously monitors VCC.
When VCC falls to the power fail detect trip point,
the RST pulls low (open drain) and remains low on
power-up for tREC after VCC passes VPFD(max).
The RST pin is an open drain output and an appro-
priate pull-up resistor should be chosen to control
rise time.
Figure 19. RSTIN Timing Waveform
Reset Input (RSTIN)
The M41ST84Y/W provides an independent input
which can generate an output reset. The duration
and function of this reset is identical to a reset gen-
erated by a power cycle. Table 12, page 21 and
Figure 19, page 21 illustrate the AC reset charac-
teristics of this function. Pulses shorter than tRLRH
will not generate a reset condition. RSTIN is inter-
nally pulled up to VCC through a 100kΩ resistor.
RSTIN
tRLRH
RST (1)
tRHRSH
Note: With pull-up resistor
AI03682
Table 12. Reset AC Characteristics
Symbol
Parameter(1)
Min
Max
Unit
tRLRH(2)
RSTIN Low to RSTIN High
200
ns
tRHRSH(3)
RSTIN High to RST High
40
200
ms
Note: 1. Valid for Ambient Operating Temperature: TA = –40 to 85°C; VCC = 2.7 to 3.6V or 4.5 to 5.5V (except where noted).
2. Pulse width less than 50ns will result in no RESET (for noise immunity).
3. Programmable (see Table 14, page 23)