M54/M74HC221/221A
AC ELECTRICAL CHARACTERISTICS (CL = 50 pF, Input tr = tf = 6 ns)
Symbol
Parameter
Test Conditions
VCC
(V)
TA = 25 oC
54HC and 74HC
Value
-40 to 85 oC -55 to 125 oC Unit
74HC
54HC
Min. Typ. Max. Min. Max. Min. Max.
tTLH Output Transition 2.0
tTHL Time
4.5
30 75
8
15
95
110
19
22
ns
6.0
7
13
16
19
tPLH Propagation
2.0
tPHL Delay Time
4.5
(A, B - Q, Q)
6.0
102 210
265
315
30 42
53
63
ns
24 36
45
54
tPLH Propagation
2.0
tPHL Delay Time
4.5
(CLRTRIGGER- Q,Q) 6.0
102 235
295
355
30 47
59
71
ns
24 40
50
60
tPLH Propagation
2.0
tPHL Delay Time
4.5
(CLR - Q, Q)
6.0
67 160
200
240
20 32
40
48
ns
16 27
34
41
tWOUT Output Pulse
2.0 CX = 100 pF
1.5
Width
4.5 RX = 10 KΩ
1.3
µs
(for HC221)
6.0
1.2
2.0 CX = 0.1 µF
7
4.5 RX = 100 KΩ
6.9
ms
6.0
6.9
tWOUT Output Pulse
2.0 CX = 100 pF
1.8
Width
4.5 RX = 10 KΩ
1.5
µs
(for HC221A)
6.0
1.4
2.0 CX = 0.1 µF
10
4.5 RX = 100 KΩ
9.7
ms
6.0
9.6
∆tWOUT Output Pulse
±1
Width Error
Between Circuits
%
in Same Package
tW(H) Minimum Pulse
2.0
tW(L) Width
4.5
75
95
110
15
19
22
ns
6.0
13
16
20
tW(L) Minimum Pulse
2.0
Width
4.5
75
95
110
15
19
22
ns
6.0
13
16
20
CIN
CPD (*)
Input Capacitance
Power Dissipation
Capacitance
5
10
10
10 pF
174
pF
(*) CPD is defined as the value of the IC’s internal equivalent capacitance which is calculated from the operating current consumption without load.
(RefertoTestCircuit). Average operting current canbeobtained by the following equation. ICC(opr) =CPD •VCC •fIN +ICC’ Duty/100 + IC/2 (per monostable)
(ICC’: Active Supply Current) (Duty:%)
7/14