GaAs SP3T 2.6 V CDMA-GPS Switch
0.5 - 3.0 GHz
Typical Performance Curves
Insertion Loss
2.0
GPS
1.5
PCS
CELL
1.0
0.5
0.0
0
1
2
3
4
5
6
Frequency (GHz)
Truth Table 7,8
V1
V2
V3
1
0
0
0
1
0
0
0
1
ANT–
GPS
On
Off
Off
ANT -
PCS
Off
On
Off
ANT -
CELL
Off
Off
On
7. Differential voltage, V (state 1) - V (state 0), must be +2.6 V
minimum, but must not exceed +8.5 V.
8. 0 = -5 V to +2.4 V, 1 = -2.4 V to +5 V.
Lead-Free 2 mm 8-Lead STDFN†
RoHS
Compliant
MASWSS0191
V1
Isolation
40
35
30
25
20
15
10
5
0
0
1
GPS
PCS
CELL
2
3
4
5
6
Frequency (GHz)
Handling Procedures
Please observe the following precautions to avoid
damage:
Static Sensitivity
Gallium Arsenide Integrted Circuits are sensitive to
electrostatic discharge (ESD) and can be damaged
by static electricity. Proper ESD control techniques
should be used when handling these devices.
† Reference Application Note M538 for lead-free solder reflow recommendations.
3
M/A-COM Inc. and its affiliates reserve the right to make changes to the
• North America Tel: 800.366.2266 / Fax: 978.366.2266
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
whatsoever arising out of the use or application of any product(s) or
information.
Visit www.macom.com for additional data sheets and product information.