Table 3. AC Electrical Characteristics (Refer to Timing Diagram Figure 3 and Figure 4. TA = 25°C, VDD = 9.0 V,
Component Values from Figure 5.) (continued)
No. Symbol
Parameter
Test Condition
Clocks Min(1) Typ(2)
Max(1)
Unit
13
tCH Silver and Brass Chirp Pulse Period Low Supply or Degraded
4096 38.9
43
Chamber Sensitivity
47.1
s
14 tW(CH) Silver and Brass Chirp Pulse Width Low Supply or Degraded
1.0
9.5
10.5
Chamber Sensitivity
11.5
ms
15
tRR Rising Edge on IO to Smoke Alarm Remote Smoke, No local
—
—
2 sec(3)
—
Response Time
smoke
16
tstb Strobe Out Pulse Period
17
Smoke Test
1024 9.67
10.8
11.83
s
Chamber Sensitivity Test
4096 38.9
43
47.1
s
Without Local Smoke
18
Low Supply Test Without Local 4096 38.9
43
47.1
s
Smoke
19
Pushbutton Test/Speed-Up 128
1.2
1.3
1.5
s
20 tMUTE Mute time
Local smoke
—
7.0
10
14
min
1. Oscillator period T (T = Tr + Tf) is determined by the external components R1, R2 and C3 where Tr = (0.6931)R2*C3 and Tf = (0.6931)R1*C3.
The other timing characteristics are some multiple of the oscillator timing shown in the table. The timing shown should accommodate the
NFPA72, ANSI S3.41, and ISO8201 audible emergency evacuation signals.
2. Typicals are not guaranteed.
3. Time is typical-depends on what point in cycle the signal is applied.