MCP2122
FIGURE 4-5:
RESET AND DEVICE RESET TIMER TIMING
VDD
RESET
Internal
RESET
TXIR Pin
RX Pin
30
34A
34A
34B
34B
TABLE 4-5: RESET AND DEVICE RESET TIMER REQUIREMENTS
AC Characteristics
Standard Operating Conditions (unless otherwise specified)
Operating Temperature: –40°C ≤ TA ≤ +125°C (Extended)
Operating Voltage VDD range is described in
Section 4.1 “DC Characteristics”.
Param.
No.
Sym
Characteristic
Min
Typ (1) Max Units
Conditions
30 TRSTL RESET Pulse Width (low)
2000
—
—
ns VDD = 5.0 V
34A
ToD Default output state of TXIR
—
pin from RESET Low
—
2
µs
34B
ToD Default output state of RX
—
—
2
µs
pins from RESET Low
Note 1: Data in the Typical (“Typ”) column is at 5V, +25°C unless otherwise stated. These parameters are for design
guidance only and are not tested.
© 2007 Microchip Technology Inc.
Preliminary
DS21894C-page 23