KA79LXXA
Electrical Characteristics(KA79L12A)
(VI = -19V, IO = 40mA, CI = 0.33µF, CO = 0.1µF, 0°C ≤TJ ≤ +125°C, unless otherwise specified)
Parameter
Output Voltage
Line Regulation (Note1)
Symbol
VO
∆VO
Conditions
TJ = +25 °C
TJ = +25 °C
-14.5V ≥VI ≥-27V
-16V≥VI ≥-27V
Min. Typ. Max. Unit
-11.5 -12.0 -12.5 V
-
- 250 mV
-
- 200 mV
Load Regulation (Note1)
Output Voltage
Quiescent Current
Quiescent Current with line
Change
with load
Output Noise Voltage
Ripple Rejection
Dropout Voltage
∆VO
VO
IQ
∆IQ
∆IQ
VN
RR
VD
TJ = +25 °C
1.0mA≤ IO ≤100mA -
1.0mA≤ IO ≤40mA
-
- 100 mV
- 50 mV
-14.5V >VI > -27V, 1.0mA ≤IO ≤ 40mA -11.4 - -12.6 V
VI = -19V, 1.0mA ≤ IO ≤ 70mA
-11.4 - -12.6 V
TJ = +25 °C
TJ = +125 °C
-
- 6.0
mA
-
- 6.5
-16V ≥ VI ≥ -27V
-
- 1.5 mA
1.0mA ≤ IO ≤ 40mA
-
- 0.1 mA
TA = +25°C,10Hz ≤ f ≤ 100KHz
- 80 -
µV
f = 120Hz, -15V ≥ VI ≥ -25V
TJ = +25°C
37 42 -
dB
TJ = +25°C
- 1.7 -
V
Note
1. Load and line regulation are specified at constant junction temperature. Change in VO due to heating effects must be taken
into account separately. Pulse testing with low duty is used.
4