ST7070
EXT = 1
Used internal resister only
provide 1/5 bias mode .
Bias resistor
Rb[1:0]=00 External
select
0
0
0
0
0
0
0
1 Rb1 Rb0 Resister
Rb[1:0]=01~11 Internal
Resistor
COM、SEG
direction
0
select
0
0
1
0
C1:com1~8 com8~1
C2:com9~16 com16~9
0 C1 C2 S1 S2 S1:seg1~40 seg40~1
S2:seg41~80 seg80~41
Set display
To specify the number of
data length 0 0 1 L6 L5 L4 L3 L2 L1 L0 data bytes(3SPI mode)
37 us
37 us
37 us
Note:
Be sure the ST7070 is not in the busy state (BF = 0) before sending an instruction from the MPU to the ST7070.
If an instruction is sent without checking the busy flag, the time between the first instruction and next instruction
will take much longer than the instruction time itself. Refer to Instruction Table for the list of each instruction
execution time.
V1.4
16/51