First Prev 21 22 23 24 25 26 27 28 29 30 Next Last
ST802RT1A, ST802RT1B
Registers and descriptors description
Table 11. RN01 [0d01, 0x01]: Status register
Bit
Bit name
Description
Default
RW
type
Type
15
100BASE-T4 0 -> PHY not able to perform 100BASE-T4
ABILITY Fixed to 0
0 RO P
14
100BASE-X 1 -> PHY able to perform full-duplex 100BASE-X
Full Duplex Fixed to 1, internally not used
13
100BASE-X 1 -> PHY able to perform half-duplex 100BASE-X
Half Duplex Fixed to 1
1 RO P
1 RO P
12
10BASE-T 1 -> PHY able to perform full-duplex 10BASE-T
Full Duplex Fixed to 1, internally not used
1 RO P
11
10BASE-T 1 -> PHY able to perform half-duplex 10BASE-T
Half Duplex Fixed to 1
1 RO P
10 RESERVED Not used
0
RO P
9 RESERVED Not used
0
RO P
8 RESERVED Not used
0
RO P
7 RESERVED Not used
6
MF Preamble
Suppression
1 -> Accepts management frames with preamble suppressed
0 -> Doesn't accept management frames without preamble
Controlled by RN14 [1].
0
RO P
1 RO -
5
Auto-
Negotiation
complete
1 -> Auto-negotiation process completed, registers 4, 5, 6 are now
valid
0 -> Auto-negotiation process not completed
Active only if auto-negotiation is enabled, else 0
0
RO -
1 -> Remote fault condition detected
0 -> No remote fault condition detected
Set when link partner signals a remote fault condition (RN05 - bit
4 Remote Fault 13) or a far-end-fault indicator was asserted. Latched, so the
0 RO LH
occurrence of a remote fault causes the remote fault bit to become
set and remain set until it is cleared (by register read, if no more
fault is present).
3
Auto-
Negotiation
Ability
1 -> PHY is able to perform auto-negotiation
Fixed to 1
1 RO P
1 -> Link is valid and established (either for 10 and 100 Mb/s)
2
Link Status
0 -> Link is down
This bit is cleared at link failure and set after a register read if a
valid link is established
1 -> Jabber condition detected: transmission exceeded max
number of bytes
0 -> No jabber condition detected.
1 Jabber Detect
Set at jabber condition detection, cleared only after register read
(if no more jabber condition is present).
Working on 10Base-T only. Fixed to 0 in 100Base-X modes
0 RO LL
0 RO LH
0
Extended 1 -> extended register capabilities
Capability Fixed to 1
1 RO P
Doc ID 17049 Rev 1
21/58

Share Link: 