Electrical Characteristics (Ta = 25°C)
TK12A60D
Characteristics
Gate leakage current
Drain cut-off current
Drain-source breakdown voltage
Gate threshold voltage
Drain-source ON resistance
Forward transfer admittance
Input capacitance
Reverse transfer capacitance
Output capacitance
Rise time
Switching time
Turn-on time
Fall time
Turn-off time
Total gate charge
Gate-source charge
Gate-drain charge
Symbol
Test Condition
Min Typ. Max Unit
IGSS
IDSS
V (BR) DSS
Vth
RDS (ON)
|Yfs|
Ciss
Crss
Coss
VGS = ±30 V, VDS = 0 V
VDS = 600 V, VGS = 0 V
ID = 10 mA, VGS = 0 V
VDS = 10 V, ID = 1 mA
VGS = 10 V, ID = 6 A
VDS = 10 V, ID = 6 A
VDS = 25 V, VGS = 0 V, f = 1 MHz
⎯
⎯
±1
μA
⎯
⎯
10
μA
600 ⎯
⎯
V
2.0
⎯
4.0
V
⎯ 0.45 0.55 Ω
1.9 7.5
⎯
S
⎯ 1800 ⎯
⎯
9
⎯
pF
⎯ 190 ⎯
tr
10 V
VGS
0V
ID = 6 A VOUT
⎯
40
⎯
ton
50 Ω
RL = 33 Ω
⎯
80
⎯
ns
tf
⎯
15
⎯
VDD ≈ 200 V
toff
Duty ≤ 1%, tw = 10 μs
⎯
110
⎯
Qg
Qgs
VDD ≈ 400 V, VGS = 10 V, ID = 12 A
⎯
38
⎯
⎯
24
⎯
nC
Qgd
⎯
14
⎯
Source-Drain Ratings and Characteristics (Ta = 25°C)
Characteristics
Continuous drain reverse current
(Note 1)
Pulse drain reverse current
(Note 1)
Forward voltage (diode)
Reverse recovery time
Reverse recovery charge
Symbol
IDR
IDRP
VDSF
trr
Qrr
Test Condition
⎯
⎯
IDR = 12 A, VGS = 0 V
IDR = 12 A, VGS = 0 V,
dIDR/dt = 100 A/μs
Min Typ. Max Unit
⎯
⎯
12
A
⎯
⎯
48
A
⎯
⎯
−1.7
V
⎯ 1200 ⎯
ns
⎯
13
⎯
μC
Marking
K12A60D
Note 4 : A line under a Lot No. identifies the indication of product Labels
[[G]]/RoHS COMPATIBLE or [[G]]/RoHS [[Pb]]
Part No.
(or abbreviation code)
Lot No.
Note 4
Please contact your TOSHIBA sales representative for details as to
environmental matters such as the RoHS compatibility of Product.
The RoHS is Directive 2002/95/EC of the European Parliament and
of the Council of 27 January 2003 on the restriction of the use of certain
hazardous substances in electrical and electronic equipment.
2