Typical Uses of MULTI-FUNCTION (M) Pin (cont.)
TOP242-250
+
DC
Input
Voltage
RIL
ON/OFF
QR
4-7 kΩ
QR can be an optocoupler
output or can be replaced
by a manual switch.
For RIL = 12 kΩ
ILIMIT = 69%
D
M
For RIL = 25 kΩ
ILIMIT = 43%
CONTROL
C
S
PI-2520-040501
Figure 38. Active-on Remote ON/OFF with Externally Set Current
Limit (See M Pin Operation Description).
+
QR can be an optocoupler
output or can be replaced
by a manual switch.
QR
DC
ON/OFF
47 kΩ
Input
Voltage
RMC
D
M
RIL 12 kΩ
CONTROL
C
24 kΩ
RMC = 2RIL
-
S
PI-2521-040501
Figure 39. Active-off Remote ON/OFF with Externally Set Current
Limit (See M Pin Operation Description).
+
QR can be an optocoupler
output or can be replaced
RLS 2 MΩ
by a manual switch.
QR
DC ON/OFF
Input
47 kΩ
Voltage
D
M
CONTROL
C
For RLS = 2 MΩ
VUV = 100 VDC
VOV = 450 VDC
-
S
PI-2523-040501
Figure 40. Active-off Remote ON/OFF with LINE-SENSE.
19 M