µPC1909
ELECTRICAL SPECIFICATIONS
Absolute Maximum Ratings (Unless otherwise specified, TA = 25°C)
Parameter
Symbol
µPC1909CX
µPC1909GS
Unit
Supply Voltage
VCC
26
V
Output Current (DC, per output)
IC (DC)
100
mA
Output Current (peak, per output)
IC (peak)
1.2
A
Total Power Dissipation
PT
1000
694
mW
Operating Ambient Temperature
TA
−20 to +85
°C
Operating Junction Temperature
TJ
−20 to +150
°C
Storage Temperature
Tstg
−55 to +150
°C
Caution Product quality may suffer if the absolute maximum rating is exceeded even momentarily for any
parameter. That is, the absolute maximum ratings are rated values at which the product is on
the verge of suffering physical damage, and therefore the product must be used under
conditions that ensure that the absolute maximum ratings are not exceeded.
Recommended Operating Conditions
Parameter
Supply Voltage
Oscillation Frequency
Output Load Capacitance
Output Load Resistance
Operating Junction Temperature
Symbol
MIN.
TYP.
MAX.
Unit
VCC
7
10
24
V
fOSC
50
200
500
kHz
CL
2200
3000
pF
RL
10
kΩ
TJ
−20
+100
°C
4
Data Sheet G14309EJ1V0DS00