SUB-CLAUSE NUMBER AND TEST
TYPE TESTS
5.16.3.0 Initial measurements
5.16.3.1 Destruction test sequence
High DC voltage test
High AC voltage test
5.16.3.2 Final measurements
CONDITIONS
Capacitance at 1 kHz
at Tmax. = 85 °C
Product enveloped with cheese cloth
3 x UNDC or DC voltage
Until repetitive product healings occur
Duration = 15 min
ACRMS voltage = UNDC/2 2
with minimum of 250 VAC
Duration = 5 min
Repeat destruction sequence 3 x
Visual examination
MKP1848 DC-Link
Vishay Roederstein
PERFORMANCE REQUIREMENTS
Audible healings or check healings with
oscilloscope
No puncturing or flashover
Self healing punctures are permitted