4-(1). Ambient temperature characteristics
(1 Form A type)
Tested sample: JQ1aP-24V
Contact carrying current: 5 A, 10 A
400
1
2
300
200
3
5
4
100
6
7
0 20 30 40 50 60 70 80 90
Ambient temperature, °C
4-(2). Ambient temperature characteristics
(1 Form C type)
Tested sample: JQ1P-24V
Contact carrying current: 5 A, 10 A
400
300
1
2
200
5
3
4
100
6
7
0 20 30 40 50 60 70 80 90
Ambient temperature, °C
JQ
1 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 130°C 266°F) (Carrying current: 5 A)
2 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 130°C 266°F) (Carrying current: 10 A)
3 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 115°C 239°F) (Carrying current: 5 A)
4 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 115°C 239°F) (Carrying current: 10 A)
5 Pick-up voltage with a hot-start condition
of 100%V on the coil (Carrying current: 10 A)
6 Pick-up voltage with a hot-start condition
of 100%V on the coil (Carrying current: 5 A)
7 Pick-up voltage
For Cautions for Use, see Relay Technical Information (Page 11 to 39).
12/27/2002
All Rights Reserved, © Copyright Matsushita Electric Works, L7td5.
Go To Online Catalog