DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

BTS550P データシートの表示(PDF) - Siemens AG

部品番号
コンポーネント説明
メーカー
BTS550P Datasheet PDF : 15 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Parameter and Conditions
at Tj = -40 ... +150 °C, Vbb = 12 V unless otherwise specified
Preliminary Data Sheet BTS550P
Symbol
Values
Unit
min typ max
Operating Parameters
Operating voltage (VIN = 0) 8, 12)
Undervoltage shutdown 13)
Undervoltage start of charge pump
see diagram page 14
Overvoltage protection14)
Tj =-40°C:
Ibb = 15 mA
Tj = 25...+150°C:
Standby current
IIN = 0
Tj =-40...+25°C:
Tj = 150°C:
Vbb(on)
VbIN(u)
VbIN(ucp)
VbIN(Z)
Ibb(off)
Protection Functions
Short circuit current limit (Tab to pins 1,5)
VON = 12 V, time until shutdown max. 350 µs Tc =-40°C:
Tc =25°C:
Tc =+150°C:
Short circuit shutdown delay after input current
positive slope, VON > VON(SC)
min. value valid only if input "off-signal" time exceeds 30 µs
Output clamp 15)
(inductive load switch off)
IL= 40 mA:
IL= 20 A:
Output clamp (inductive load switch off)
at VOUT = Vbb - VON(CL) (e.g. overvoltage)
IL= 40 mA
Short circuit shutdown detection voltage
(pin 3 to pins 1,5)
Thermal overload trip temperature
Thermal hysteresis
IL(SCp)
td(SC)
-VOUT(CL)
VON(CL)
VON(SC)
Tjt
Tjt
5.0
-- 34 V
2.0 3.0 4.5 V
3.5 4.5 6.0 V
60
--
-- V
62 66
--
-- 15 25 µA
-- 25 50
-- 170
-- A
-- 180 250
120 170
--
80
-- 350 µs
-- 16.8
-- 19.0
-- V
--
39 42 46.5 V
--
6
150
--
-- 10
-- V
-- °C
-- K
12) If the device is turned on before a Vbb-decrease, the operating voltage range is extended down to VbIN(u).
For the voltage range 0..34 V the device is fully protected against overtemperature and short circuit.
13) VbIN = Vbb - VIN see diagram on page 6. When VbIN increases from less than VbIN(u) up to VbIN(ucp) = 5 V
(typ.) the charge pump is not active and VOUT Vbb - 3 V.
14) See also VON(CL) in circuit diagram on page 7.
15) This output clamp can be "switched off" by using an additional diode at the IS-Pin (see page 7). If the diode
is used, VOUT is clamped to Vbb- VON(CL) at inductive load switch off.
Semiconductor Group
Page 4
1998-Aug-31

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]