B41554
SIKOREL 125 °C
Specifications and characteristics in brief
Rated voltage VR
Surge voltage VS
Rated capacitance CR
Capacitance tolerance
Leakage current Ileak
(5 min, 20 °C)
16 ... 100 V DC
1.15 VR
1500 ... 220000 µF
10/+30% Q
Self-inductance ESL
d = 35.7 mm: approx. 10 nH
d = 51.6 mm: approx. 15 nH
d ≥ 64.3 mm: approx. 20 nH
Useful life
125 °C; VR; IAC,R
85 °C; VR; IAC,max
40 °C; VR; 3.4 IAC,R
40 °C; VR; 3.8 IAC,R
Voltage endurance test
125 °C; VR; IAC,R
Vibration resistance test
d ≤ 51.6 mm d ≥ 64.3 mm Requirements:
> 2500 h > 5000 h
∆C/C ≤ ±45% of initial value
> 15000 h > 25000 h ESR ≤ 3 times initial specified limit
> 200000 h
Ileak
≤ initial specified limit
> 200000 h
Post test requirements:
2000 h
∆C/C ≤ ±15% of initial value
ESR ≤ 1.3 times initial specified limit
Ileak
≤ initial specified limit
To IEC 60068-2-6, test Fc:
Displacement amplitude 0.75 mm, frequency range 10 ... 55 Hz,
acceleration max. 10 g, duration 3 × 2 h.
Capacitor mounted by its body which is rigidly clamped to the work
surface.
IEC climatic category
Detail specification
Sectional specification
To IEC 60068-1:
55/125/56 (55 °C/+125 °C/56 days damp heat test)
Similar to CECC 30301-804
IEC 60384-4
Ripple current capability
Due to the ripple current capability of the contact elements, the following current upper limits must
not be exceeded:
Capacitor diameter
IAC, max
≤ 51.6 mm
30 A
> 51.6 mm
40 A
Please read Cautions and warnings and
Important notes at the end of this document.
Page 3 of 17