54-94-104MT..KPbF Series
Vishay High Power Products Three Phase AC Switch
(Power Modules), 50 A to 100 A
750
At any rated load condition and with
700
rated VRRM applied following surge.
Initial TJ = 125 °C
650
at 60 Hz 0.0083 s
at 50 Hz 0.0100 s
600
550
500
450
400 94MT..K Series
Per junction
350
1
10
100
Number of Equal Amplitude Half
Cycle Current Pulses (N)
Fig. 9 - Maximum Non-Repetitive Surge Current
130
104MT..K Series
120
Device fully turned-on
110
100
90
Per single AC switch
80
~
IRMS
70
For all conduction angles
60
0
20
40
60
80
100 120
RMS Output Current (A)
Fig. 11 - Current Ratings Characteristic
1000
900
800
700
Maximum non-repetitive surge current
versus pulse train duration. Control
of conduction may not be maintained.
Initial TJ = 125 °C
No voltage reapplied
Rated VRRM reapplied
600
500
400 94MT..K Series
Per junction
300
0.01
0.1
1
Pulse Train Duration (s)
Fig. 10 - Maximum Non-Repetitive Surge Current
1000
100
TJ = 25 °C
10
TJ = 125 °C
104MT..K Series
Per junction
1
0
1
2
3
4
5
Instantaneous On-State Voltage (V)
Fig. 12 - Forward Voltage Drop Characteristics
500
450
400
350
104MT..K Series
TJ = 125 °C
Device fully
turned-on
180°
120°
90°
60°
30°
300
Ø
250
Ø
200
Conduction angle
150
100
50
0
0
20
40
60
80
100 120
500
450
400
350
0.15 K/W
300
250
0.3 K/W
200 0.5 K/W
150 0.7 K/W
100 1.0 K/W
50 1.5 K/W
0
0
25
50
75
100
125
RMS Output Current (A)
Maximum Allowable Ambient
Temperature (°C)
Fig. 13 - Total Power Loss Characteristics
www.vishay.com
6
For technical questions, contact: ind-modules@vishay.com
Document Number: 94351
Revision: 05-May-08