¡ Semiconductor
FEDL9202-04
MSM9202-01
AC Characteristics-1
Parameter
CP Frequency
CP Pulse Width
DA Setup Time
DA Hold Time
CS Setup Time
CS Hold Time
CS Wait Time
Data Processing Time
RESET Pulse Width
RESET Time
DA Wait Time
All Output Slew Rate
VDD Rise Time
VDD Off Time
(VDD=5.0V±10%, VFL=–60V, Ta=–40 to +85°C, unless otherwise specified)
Symbol
fC
tCW
tDS
tDH
tCSS
tCSH
tCSW
tDOFF
tWRES
tRSON
tRSOFF
tR
tF
tPRZ
tPOF
Condition
—
—
—
—
—
R1=3.3kW, C1=47pF
—
R1=3.3kW, C1=47pF
When RESET signal is input from
microcontroller etc. externally
When RESET signal is input from
microcontroller etc. externally
R2=1.0kW, C2=0.1mF
—
Cl=100pF
tR=20% to 80%
tF=80% to 20%
When mounted in the unit
When mounted in the unit, VDD=0.0V
Min.
—
250
250
250
250
16
250
8
250
250
—
250
—
—
—
5.0
Max. Unit
2.0 MHz
—
ns
—
ns
—
ns
—
ns
—
ms
—
ns
—
ms
—
ns
—
ns
200 ms
—
ns
2.0
ms
2.0
ms
100 ms
—
ms
AC Characteristics-2
Parameter
CP Frequency
CP Pulse Width
DA Setup Time
DA Hold Time
CS Setup Time
CS Hold Time
CS Wait Time
Data Processing Time
RESET Pulse Width
RESET Time
DA Wait Time
All Output Slew Rate
VDD Rise Time
VDD Off Time
(VDD=3.3V±10%, VFL=–60V, Ta=–40 to +85°C, unless otherwise specified)
Symbol
Condition
Min. Max. Unit
fC
—
—
tCW
—
250
tDS
—
250
tDH
—
250
tCSS
—
250
tCSH
R1=3.3kW, C1=39pF
16
tCSW
—
250
tDOFF
R1=3.3kW, C1=39pF
8
tWRES
When RESET signal is input from
microcontroller etc. externally
250
When RESET signal is input from
tRSON
microcontroller etc. externally
250
R2=1.0kW, C2=0.1mF
—
tRSOFF
—
250
tR
tF
Cl=100pF
tR=20% to 80%
—
tF=80% to 20%
—
tPRZ
When mounted in the unit
—
tPOF When mounted in the unit, VDD=0.0V
5.0
2.0 MHz
—
ns
—
ns
—
ns
—
ns
—
ms
—
ns
—
ms
—
ns
—
ns
200 ms
—
ns
2.0
ms
2.0
ms
100 ms
—
ms
10/33