M34D64-W
DC and AC parameters
Table 10. DC characteristics
Symbol
Parameter
Test condition (in addition to
those in Table 7)
Min.
Max. Unit
ILI
Input leakage current
(SCL, SDA)
VIN = VSS or VCC
device in Standby mode
± 2 µA
ILO Output leakage current
ICC Supply current
VOUT = VSS or VCC, SDA in Hi-Z
VCC = 2.5 V, fc= 400 kHz
(rise/fall time < 50 ns)
± 2 µA
1 mA
ICC1 Standby supply current
Input low voltage
VIL (E2, E1, E0, SCL, SDA)
Input low voltage (WC)
VIN = VSS or VCC, VCC = 5 V
VIN = VSS or VCC, VCC = 2.5 V
10 µA
2 µA
–0.3 0.3VCC V
–0.3 0.5 V
VIH
Input high voltage
(E2, E1, E0, SCL, SDA, WC)
0.7VCC VCC+1 V
VOL Output low voltage
IOL = 2.1 mA, VCC = 2.5 V
0.4 V
21/27