AC CHARACTERISTICS
VID
VIH
OE# VSS
DATA SHEET
A18 – A0
XXXh
Valid (Note 2)
D7 – D0
60h
60h
Valid (Note 2)
40h
Array Data
CE#
WE#
Sector Unlock sequence (three cycles)
Notes:
1. To enable the command mode sector protection/unprotection
algorithm, the system must issue the command 24h in the sector
unlock sequence.
2. For sector protection, a valid address consists of the sector
address with A6 = 0, A5 = 1, A1 = 1, A0 = 0. For sector
Sector Relock sequence (two cycles)
unprotection, a valid address consists of the sector address with
A6 = 1, A5 = 1, A1 = 1, A0 = 0.
Figure 18. Sector Protect/Unprotect Timing Diagram
May 9, 2006 Am29F004B_00_E4
Am29F004B
29